Language

logo suntechlogo kyoceralogo hyundailogo rec

Panouri fotovoltaice HYUNDAI

Panou fotovoltaic HYUNDAI cod HIS-S SF

HIS-S SF
188 191 194 197 200 203 206 209 212
Nominal output (Pmax) W 188 191 194 197 200 203 206 209 212
Warranted minimum power W 182.4 185.3 188.2 191.1 194.0 196.9 199.8 202.7 205.6
Voltage at Pmax (Vpm) V 25.0 25.2 25.6 25.9 26.3 26.5 26.8 26.9 27.0
Current at Pmax (Ipm) A 7.5 7.6 7.6 7.6 7.6 7.7 7.7 7.8 7.9
Open circuit voltage (Voc) V 33.0 33.2 33.2 33.3 33.4 33.4 33.5 33.5 33.5
Short circuit current (Isc) A 8.1 8.2 8.2 8.2 8.3 8.3 8.4 8.5 8.6
Output tolerance % ± 3% ± 3% ± 3% ± 3% ± 3% ± 3% ± 3% ± 3% ± 3%
No. of cells & connection pcs 54 in series
Cell type - 6" Mono-crystalline silicon
Cell efficiency % 14.8 15.0 15.3 15.5 15.8 16.0 16.3 16.5 16.8
Module efficiency % 13.0 13.2 13.4 13.6 13.8 14.0 14.2 14.4 14.6
Temperature coefficient of Pmax %/K -0.44 -0.44 -0.44 -0.44 -0.44 -0.44 -0.44 -0.44 -0.44
Temperature coefficient of Voc %/K -0.34 -0.34 -0.34 -0.34 -0.34 -0.34 -0.34 -0.34 -0.34
Temperature coefficient of Isc %/K 0.052 0.052 0.052 0.052 0.052 0.052 0.052 0.052 0.052
* All data at STC (Standar Test Conditions). Above data may by changed without prior notice.

hyundai HIS-S-SF

Panou fotovoltaic HYUNDAI cod HIS-M SF

HIS-M SF
182 185 188 191 194 197 200 203 206
Nominal output (Pmax) W 182 185 188 191 194 197 200 203 206
Warranted minimum power W 176.5 179.5 182.4 185.3 188.2 191.1 194.0 196.9 199.8
Voltage at Pmax (Vpm) V 25.9 26.0 26.2 26.3 26.4 26.6 26.7 26.9 27.1
Current at Pmax (Ipm) A 7.1 7.1 7.2 7.3 7.3 7.4 7.5 7.5 7.6
Open circuit voltage (Voc) V 32.7 32.8 33.0 33.0 33.1 33.3 33.6 33.7 33.8
Short circuit current (Isc) A 7.8 7.8 7.9 8.0 8.0 8.1 8.2 8.3 8.3
Output tolerance % ± 3% ± 3% ± 3% ± 3% ± 3% ± 3% ± 3% ± 3% ± 3%
No. of cells & connection pcs 54 in series
Cell type - 6" Multi-crystalline silicon
Cell efficiency % 13.9 14.1 14.3 14.5 14.8 15.0 15.2 15.4 15.6
Module efficiency % 12.6 12.8 13.0 13.2 13.4 13.6 13.8 14.0 14.2
Temperature coefficient of Pmax %/K -0.43 -0.43 -0.43 -0.43 -0.43 -0.43 -0.43 -0.43 -0.43
Temperature coefficient of Voc %/K -0.32 -0.32 -0.32 -0.32 -0.32 -0.32 -0.32 -0.32 -0.32
Temperature coefficient of Isc %/K 0.056 0.056 0.056 0.056 0.056 0.056 0.056 0.056 0.056
* All data at STC (Standar Test Conditions). Above data may by changed without prior notice.

hyundai HIS-M-SF

logo eltex solar alb

Str. Matei Basarab, nr. 55A,  Mangalia, 905500
Telefon: 0241 75 99 87
Fax: 0241 75 99 87
Mobil: 0722 310 242; 0748 221.137

This email address is being protected from spambots. You need JavaScript enabled to view it.



DSCN8336DSCN8349
RENEXPO
SOUTH-EAST EUROPE

ELTEX SOLAR a participat in perioada 21-23.11.2012 la "Al V-lea targ international pentru energie al Romaniei"